Release 10.1A: OpenEdge Data Management:
Database Administration
Internal Code Page (-cpinternal)
Operating systemand syntax UNIXWindows-cpinternalcodepage Usewith Maximum value Minimum value Single-user default Multi-user default CS, DBS, DS – – iso8859-1 iso8859-1
codepageThe name of the code page used in memory.
Use Internal Code Page (-
Note: Do not use a 7-bit table with -cpinternal) to identify the code page used in memory and for graphical clients. For graphical clients, the -cpinternalcode page should be the same code page that the operating system uses. If you do not use -cpinternal, the iso8859-1 code page is used by default. To retrieve the value of this startup parameter at run time, use theCPINTERNALattribute of theSESSIONSystem handle.cpinternal. Use 7-bit tables for converting data from a 7-bit terminal to another code page only. Do not use them for character conversion in memory or for the database.
|
Copyright © 2005 Progress Software Corporation www.progress.com Voice: (781) 280-4000 Fax: (781) 280-4095 |